Why contact terminals are plated

Copper alloys oxidise, and the oxide is a poor conductor. Plating keeps the surface conductive, limits fretting corrosion and controls wear across mating cycles.
Gold is chosen for low and stable resistance at low force; tin for cost where force is high and cycles are few; nickel as a barrier under both. The thickness should follow the number of mating cycles, not the price target.