Back to news
Technical note
YD28 and 5015: what actually differs

Shell
5015 descends from MIL-DTL-5015 and its wall is noticeably thicker — about 1.6 times the weight of a YD28 of the same size. The thickness buys impact resistance, and it also adds mounting burden: a suspended run needs support.
Coupling
5015 is threaded, YD28 is bayonet. A thread resists vibration-induced loosening better but mates slowly; a bayonet mates fast, which suits a commissioning port that is connected repeatedly.
Sealing and temperature
5015 compresses a face gasket hard enough for IP67 and runs from −55 to +125 °C. YD28 typically reaches IP65 over −40 to +105 °C.
How to choose
- Outdoor, heavy industry, defence; high vibration, infrequent service → 5015
- General industrial, frequent mating, cost-sensitive → YD28
The two do not intermate. Thread and keyway both differ — check the drawing before ordering.