Back to news

Technical note

Waterproof connectors: the IP code in practice

· 1 min read
Waterproof connectors: the IP code in practice

The first digit is solids, the second is liquids. IP67 — dust-tight, one metre for thirty minutes — is the usual industrial target; IP68 extends depth and duration by agreement between buyer and maker. Neither covers steam, and neither covers a cable entry gland that does not match the jacket.

For outdoor cabinets, add a drip loop and a breather so pressure changes do not pull water past the seal. The connector is only one part of the sealing system.