Keeping IEEE 1394 servo signals stable over long cable runs

· 1 min read
Keeping IEEE 1394 servo signals stable over long cable runs

The symptom

On long runs, position error appears at random: creep at low speed, occasional alarms at high speed. Swapping the drive and the motor changes nothing.

Three causes

  1. Shield not bonded. With the braid grounded only at the drive end, the other end floats and acts as an antenna. Bond 360° at both ends.
  2. Conductor too small. At 0.15 mm² over twenty metres the drop is significant and it eats the swing of a 5 V differential signal. Use 0.2 mm² or larger.
  3. Power and encoder cable run together. PWM couples across. Route them apart, and cross at 90° where they must.

How to confirm

Look at the differential waveform at the drive end. If eye opening falls by more than 20% over the run, check the shield first and conductor size second.