Solutions
New Energy & Storage
Generation and storage systems: high current, high voltage, and outdoor temperature extremes.
The application
A connector in a storage cabinet faces three things at once: temperature rise from high current, condensation from day-night cycling outdoors, and rough handling on site.
Temperature rise
Current capacity is not a fixed number — it depends on ambient temperature and how many contacts are loaded. At 55 °C inside a cabinet, a terminal rated 20 A often has to be derated to 14 A. Run it at the headline figure and the housing creeps, contact pressure falls, and the joint enters a downward spiral.
Installation
Site workmanship varies widely, so we favour interfaces with unambiguous feedback: a bayonet that clicks, a thread with a witness mark.
Our approach
What we specify
- Derate against the real cabinet temperature, not the headline rating
- Condensation-tolerant construction for outdoor or cycling environments
- Coupling with clear tactile or audible confirmation
- Paralleled contacts to share high-current loads
Frequently specified
- DIN 41612 H15, 15 A per contact
- 9EDGK-7.5 power terminals, 20 A
- 5015 military-pattern circular, IP67
- High-current D-SUB 21W4, power and signal in one shell