Solutions

Industrial Automation

Servo motion, inverters, CNC machines and robots — every interface between the drive and the motor.

Industrial Automation
Application view · Industrial Automation

The application

On an automated line the connector count is always highest at the servo axes. A six-axis robot carries six encoder cables and six power cables; add the MDR, 1394 and DIN 41612 interfaces inside the cabinet and a single work cell can reach a hundred connection points.

The real constraint

The failure mode here is not poor contact — it is a broken conductor inside the drag chain. The harness flexes thousands of times a day, copper work-hardens from the few-hundred-thousandth cycle, and the break almost always appears at the strain concentration just behind the connector. That is why we specify overmoulded bodies with a strain-relief cone rather than crimped tails on these projects.

What supports it

The drive-side MDR and 1394 interfaces need a complete shield bond. Without it, PWM couples into the feedback signal and shows up as low-speed creep or positioning jitter.

Our approach

Selection order

  • Motor side first: 7-pin, 4+2 pin, or European high-power
  • Then the drive side: MDR 26-way, 1394 10-way or 1394 6-way
  • Finally the harness process: overmoulded for anything that runs in a drag chain

Frequently specified

  • FS007 7-pin motor plug, IP67
  • MDR 26-way cable plug with right-angle board socket
  • IEEE 1394 10-way socket and cable plug
  • Custom encoder and power harnesses